Emerson Rosemount 3051TG3A2B21AB4E5Q4 Process Management, Rosemount Division Dust Ignition-Proof

Emerson Rosemount 3051TG3A2B21AB4E5Q4 Process Management, Rosemount Division Dust Ignition-Proof

  • Emerson Rosemount 3051TG3A2B21AB4E5Q4 Process Management, Rosemount Division Dust Ignition-Proof
Emerson Rosemount 3051TG3A2B21AB4E5Q4 Process Management, Rosemount Division Dust Ignition-Proof
Product Details:
Place of Origin: Singapore
Brand Name: Rosemount
Certification: CE, ect
Model Number: 3051TG3A2B21AB4E5Q4
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: New Original Box
Delivery Time: 3-5days
Payment Terms: T/T
Supply Ability: In Stock
Contact Now
Detailed Product Description
Product Category: Pressure Transmitters Product Number: 3051TG3A2B21AB4E5Q4
City Of Origin: Singapore Lead Time: 6weeks
Packing: Carton Pressure Measurement: Gauge
Highlight:

Rosemount 3051TG3A2B21AB4E5Q4 Process Management

,

Emerson Rosemount 3051TG3A2B21AB4E5Q4

,

Rosemount 3051TG3A2B21AB4E5Q4 Dust Ignition-Proof

 

Emerson Rosemount 3051TG3A2B21AB4E5Q4 Process Management, Rosemount Division Dust Ignition-Proof

Product Description of 3051TG3A2B21AB4E5Q4

Product Highlights Rosemount 3051T In-line Pressure transmitters provide reliable Gage and Absolute pressure measurement in a compact in-line design Gage -14.7 to 800 psi (-1.0 to 55 bar) 0 to 800 psia (0 to 55 bar) 4–20 mA with Digital Signal Based on HART Protocol 1/2–14 NPT Female 316L SST Silicone Aluminum Bracket for 2-in. Pipe or Panel Mounting, All SST FM Explosion-proof, Dust Ignition-proof Calibration Certificate

 

Verifying configuration parameters of 3051TG3A2B21AB4E5Q4
Emerson recommends verifying the following configuration parameters prior to
installation into the process:
• Alarm and Saturation Values
• Damping
• Process Variables
• Range Values
• Tag
• Transfer Function
• Units
 
Verify configuration parameters with a communication device of 3051TG3A2B21AB4E5Q4
Procedure
1. Go to Device Settings → Setup Overview → Alarm and Saturation Values to set
alarm and saturation levels.
2. Go to Device Settings → Setup Overview → Output to set damping.
3. Set the process variables:
a) To set the primary variable, go to Device Settings → Output → Analog Output
→ PV Setup.
b) To set up the other process variables, go to Device Settings →
Communication → HART → Variable Mapping.
4. To set range values, go to Device Settings → Output → Analog Output → PV Setup.
5. To set a tag, go to Device Settings → Setup Overview → Device.
6. To set transfer function, go to Device Settings → Output → Analog Output → PV
Setup.
7. Set units:
a) To set pressure units, go to Device Settings → Output → Pressure → Setup.
b) To set other units, go to Device Settings → Output → Pressure/Flow/
Totalizer/Level/Volume/Module Temperature → Setup.
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 